• Türkçe
  • İngilizce

Bi̇osafety For Health

Health Insti̇tuti̇ons

Viral, bacterial and fungal diseases due to pathogens such as MRSA (Methylene Resistance Staphylococcus aerous), MERS, SARS, Influenza in hospitals can cause severe losses when adequate hygiene measures are not taken. Bacteria that are resistant to antibiotics sometimes do not work on patients even if an antibiogram is performed.

Hospital Floor Surface Disinfection:

Biocon A is safely used for surface disinfection in areas such as corridors, walls, floors, handrails, toilets, laboratories with intense human movements thanks to its high and fast biocidal activity against viral factors. A 5 liter lid Biocon A is sufficient for cleaning and mopping water.
It is suitable for fogging with ULV for air and surface disinfection of operation rooms. Provides complete control against viral, bacterial and fungal agents. See the table below for reconstitution rates.
 

BİOCON A IRRIGATION TABLE

General Disinfection

1/200

BİOCON A FOG

PRACTICAL IRRIGATION TABLE

In Foot Deep

1/100

Biocon A quantity

ULV app. time

Amount of water (lt)

1/25

1/50

1/100

1/200

1/1000

Air Freshener Thick Droplet

1/200

3000

1 Kg

120 dak.

200

8 Kg

4 Kg

2 Kg

1 Kg

200 gr

ULV Fogging

1/25-50

150

50 gr

360 sn.

10

400 gr

200 gr

100 gr

50 gr

10 gr

Water Lines Disinfection

1/200

30

10 gr

72 sn.

5

200 gr

100 gr

50 gr

25 gr

5 gr

Continuous Disinfection of Water Lines

1/1000

1

0,33 gr

2,4 sn.

1

40 gr

20 gr

10 gr

5 gr

  1. gr

 

Fogging:

1 - PREPARATION OF SOLUTION;

Reconstitution rate 1/25 (4%): 1 Kg Biocon A is mixed with 24 lt water.
Put the water first.
Use protective gloves and mask when preparing the solution, avoid eye contact.
While adding Biocon A gradually to the water, mix using a stick.

2- APPLICATION PREPARATION;

* Cleaning and order should be provided before disinfection, and any living culture that will be damaged by disinfectant should not be left in the environment.
* The room to be fogged should be locked to prevent human and animal entry.
* A plate that says the application start time and the time that can be entered into the room at the earliest should be hung on the door.

 

CAUTION DISINFECTION APPLICATION IS AVAILABLE.

 

ONLY PERSONNEL.

 

Application Start Time:

First Entrence Time:

 

 

* The prepared solution can be drawn directly from the bucket with a bypass hose, or the amount to be used with a funnel can be placed in the tank chamber.


3- APPLICATION;

* After all measures are taken, the ULV device is operated. Solution amounts per cubic meter are given in the table below.

FOGGING Biocon A / m³ / time

  •  

Biocon A amount

ULV App. time 

  1.  

1 kg

90 min

  1.  

50 g

5 - 6 min

  1.  

17 g

2 - 3 min

  1.  

0,33 g

6 sec